Thermo Fisher Scientific facilitates pesticide detection

Tuesday, 15 February, 2011 | Supplied by: Thermo Fisher Scientific


Thermo Fisher Scientific has developed a faster screening method for pesticides, enabling labs to simultaneously screen and confirm the presence of more than 1000 pesticides, at low levels, using a single injection.

Other commonly used techniques require multiple injections in order to comply with increasingly stringent regulations. The new method, which uses the Thermo Scientific Quantum GC, can acquire 3000 timed selective reaction monitoring (SRM) transitions per run, increasing sample throughput while ensuring accuracy in a matrix. The method, detailed in an application note entitled Rapid Analysis of 303 Pesticide Residues in Green Bean Using Triple Quadrupole GC-MS/MS, is available

Gas chromatography (GC) with element-selective detectors and single quadrupole gas chromatography/mass spectrometry (GC/MS) are techniques commonly used for GC-amenable pesticide residue analysis in laboratories. As the use of pesticides increases and maximum residue levels (MRLs) set by regulations become more stringent, labs are requiring alternatives to existing techniques that require one sample be analysed using several injections and multiple methods. The latest Thermo Fisher Scientific GC-MS/MS method enables the rapid screening and confirmation of more than 1000 pesticides in just one injection, increasing productivity and, by delivering results faster, safeguarding human health.

The method is designed to facilitate compliance with the European Council Directive 96/23/EC, which requires at least two SRM transitions per compound.

In this method, scientists analysed 303 pesticides in green beans in a single run using the TSQ Quantum GC under timed-SRM mode. The timed-SRM function enabled the acquisition of a total of 652 transitions. The dwell time of each transition was automatically maximised for each compound to give the best sensitivity for all pesticides. Using this method, linearity and recoveries are achieved within industry requirements and sensitivity can easily reach 0.0040 mg/kg for all pesticides in green beans. The new method demonstrates that timed-SRM mode is an extremely effective method for screening and determining large amounts of pesticides at low levels in the sample matrix.

Online: thermofisher.com
Phone: 1300 735 292
Related Products

Marel Revo FiberFlex patty shaping and processing

Marel's Revo FiberFlex is a burger patty forming and processing system.

ifm Hygienic Flow Meter with IO-Link

The ifm Hygienic Flow Meter with IO-Link is an example of technology in the food industry that...

Aplex SiER-G1101M Modbus Gateway

The Aplex SiER-G1101M, an Industrial 1-port RS-232/422/485 Modbus Gateway, is digitising the...


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd